Series | TRIRON MODULAR | ||||||
Model | Triron1206N | Triron2210N | Triron3210N | Triron4210N | |||
Norminal system voltage | 12/24VDC Auto Work | ||||||
Rated charge current | 10A | 20A | 30A | 40A | |||
Rated charge power | 130W/12V 260W/24V | 260W/12V 520W/24V | 390W/12V 780W/24V | 520W/12V 1040W/24V | |||
Battery type | Lead-acid(Sealed)/Gel/Lithium(LiFO4) | ||||||
Max. conversion efficiency | ≤98.0% | ||||||
MPPT tracking efficiency | ≥99.50% | ||||||
Max. PV open circuit voltage | 100V①; 92V② | ||||||
MPP voltage range | (Battery voltage +2V)~72V | ||||||
Equalization voltage | Sealed:14.6V, Flooded: 14.8V, User-defined: 9-17V | ||||||
Boost voltage | Gel: 14.2V, Sealed: 14.4V, Flooded: 14.6V, User-defined: 9-17V | ||||||
Float voltage | Gel/Sealed/Flooded: 13.8V, User-defined: 9-17V | ||||||
Self Consumption | ≤14mA(12V);≤15mA(24V) | ||||||
Temperature compensation | -3mV/℃/2V(Default) | ||||||
Relative humidity | ≤95%, N.C. | ||||||
Enclosure | IP30 | ||||||
RS485 interface | 5VDC/100mA | ||||||
Grounding | Common Negative | ||||||
Operating Temp. range | -25℃~+55℃(LCD) -30℃~+55℃(NO LCD) | ||||||
Dimensions(L*W*H)mm | 135*180.8*47.3 | 150*216*56.7 | 158*238.3*62.7 | 183*256.8*66.7 | |||
Net weight | 0.56KG | 0.92KG | 1.35KG | 1.85KG | |||
Gross weight | 0.85KG | 1.3KG | 1.7KG | 2.50KG |
Interface Modules | Function | ||||||
USB COM Slave | UCS | RS485 interface: Connect to PC or phone. View or change the controller parameters. USB interface: Supplies 5VDC for electronic equipment. NOTE: USB interface is output when the load is ON. | |||||
Relay COM Master | RCM | RS485 interface: Connect to inverter. View the inverter parameters via the LCD. Relay interface: Remotely control the inverter ON/OFF. NOTE: The module can’t connect the accessories. | |||||
Relay COM Slave | RCS | RS485 interface: Connect to PC or phone. View or change the controller parameters. Relay interface: Remotely control the inverter ON/OFF. NOTE: The module can connect the accessories. | |||||
Double USB | USB1 | USB interface: Supplies 5VDC for electronic equipment. NOTE: USB interface is output when the load is ON. |
Display Modules | Description | ||||||
Display Basic1 | DB1 | LED Indicators: PV & battery working status Button: When the working mode is Manual Control, the load is ON/OFF via the button. | |||||
Display Standard 1 | DS1 | LED Indicators: PV & load working status Buttons: View or set the parameters LCD: PV display: voltage/current /generated energy Battery display: voltage/current/temperature Load: Display current/load working mode when the controller communicates with the PC or APP. Display voltage/current/ power consumption when the controller communicates with the inverter. | |||||
Display Standard 2 | DS2 | Indicators: PV & battery & load working status Buttons: View or set the parameters LCD: PV display voltage/current /generated energy/Power Battery display voltage/ current/temperature/capacity Load: Display voltage/ current/ power/ load working mode when the controller communicates with the PC or APP. Display voltage/current/power power consumption when the controller communicates with the inverter. |